VTU-500 GI GAS FUEL INJECTOR TEST RIG
1. Describe
Max. air inlet pressure | 15 Bar |
Air consumption | 600 - 2000 l/min; 7bar |
Air quality according | ISO 8573-1 |
Hydraulic output pressure
|
Max. 420 bar @ 7 bar for air(seal oil); Max. 300 bar @ 7 bar for control oil |
Max oil flow at no pressure | 3 L / min @ 7 bar for air input (control oil and sealing oil) |
Cycle frequency | 300 cycles/min air input 7 bar, no output pressure |
Oil discharge rate | 10 cm3/ time for control oil and sealing oil |
Tank capacity | 15L |
Gauges | Class 1.0 |
Nitrogen input | Min 30bar |
Power consumption | 100 - 240 V 50/60 Hz, Max 120 VA |
Weight | 350 kg |
(D x W x H)Dimensions | 520x2000x1600mm(5 valves) |
Included adapters
|
Hydraulic outlets:2 pcs of 1.5 m high pressure hose with116 (control oil) and 125(sealing oil) series couplings |
Nitrogen inlet :3.2m hoses with male G1/4 connector included | |
Nitrogen outlet :1.5m hoses with female M16X2 connector included | |
Electrical:With 5 meters of cable | |
Air inlet: Claw coupling for 1/2" hose | |
Output pressure
|
Control oil: 300 bar |
Sealing oil: 380 bar | |
N2: 350 bar |
4.Function